Investigation the Electrode Wear Rate and Metal Removal Rate in EDM Process using Taguchi and ANOVA Method

Authors

  • Safaa K. Ghazi university of technology

DOI:

https://doi.org/10.30684/etj.v38i10A.1231

Abstract

The experimental work of this paper leads to electrical discharge machining (EDM). A system for machining in this process has been developed. Many parameters are studied such as current, pulse on-time, pulse off time of the machine. The main aim of this work is to calculate the metal removal rate (MRR) and electrode wear rate (EWR) using copper, electrodes when machining tool steel H13 specimens of a thickness (4mm).

Different current rates are used ranging from (30, 42, and 54) Amp, pulse on-time ranging from (75, 100, and 125) and pulse off time ranging from (25, 50, and 75)   found that high current gives large electrode wear and metal removal rate and. The experiment design was by Taguchi Method. From an analysis of variance (ANOVA) the more active influence of input factors on the outputs is currently for metal removal rate (MRR) (58%) and electrode wear rate (EWR) (57).

Downloads

Download data is not yet available.

Published

2020-10-25

How to Cite

Ghazi, S. K. (2020). Investigation the Electrode Wear Rate and Metal Removal Rate in EDM Process using Taguchi and ANOVA Method. Engineering and Technology Journal, 38(10A), 1504-1510. https://doi.org/10.30684/etj.v38i10A.1231